An alarm profile answers three questions for lone worker protection with the online guard control system OWKS®:

  • What triggers an alarm? These are the alarm criteria, for example five minutes without activity.
  • Which devices are monitored? For example only the device from plant 1, not the one from plant 2.
  • Who is informed in an alarm? These are the alarm receivers, for example two people in the control room.

You can create several profiles and protect devices in different ways, for example night shifts more strictly than day shifts.

Prerequisites

  • You have access to the Lone Worker Protection menu.
  • The employees you want to make alarm receivers have been created as users.
  • Lone worker protection currently does not support iOS devices.

Step 1: Create an alarm profile

Open Lone Worker Protection and then Alarm profiles. Click Create alarm profile, enter a Name and click Create. Choose a name that lets you recognise the profile later, for example Night shift plant 1.

If a warning appears above the list, at least one profile has no active notification rule. No email is then sent in an alarm. Use the link in the warning to create the rule.

Step 2: Set the alarm criteria

Click the profile in the list. The Settings are on the General tab. To change them, click the pencil in the top right.

  • Permanent connection check: The device must always be connected to the server. If the connection fails for more than 5 minutes, a technical alarm is triggered.
  • Alarm / panic button on the device: A red alarm button triggers an alarm immediately. This only works with certain devices such as the Crosscall Core M5. Our sales team can answer questions about this.
  • Inactivity until time alarm: After this time without activity on the device, a time alarm is triggered. The DIN standard allows 5 to 30 minutes.
  • Pre alarm: A warning before the time alarm. The employee can reset it. The DIN standard allows 30 to 240 seconds.
  • Requires active alarm receiver: If this is switched on, work can only start once an alarm receiver has acknowledged a test alarm.
  • Operating condition can be reset by lone worker.: Despite the label, switching this on means the employee may not reset the device themselves after an alarm.
  • Phone of the alarm receiving center: The device dials this number automatically when the alarm button is pressed.

Each criterion shows the relevant section of the pre-standard, for example DIN V VDE V 0825-11 4.1.1. COREDINATE does not query the phone's motion sensors, so position and impact are not recorded.

Step 3: Assign devices and alarm receivers

On the Monitored devices tab, click Add device. The list shows the name, phone number, GPS and actions for each device.

On the Alarm receiver tab, click Add receiver. Select at least one person. They should be people who can really be reached in an alarm.

Step 4: Read the VDE check

At the top of the profile, the portal shows whether the VDE V 0825-11 pre-standard is fulfilled. Each line has a green tick or a red cross:

  • All monitored devices have a phone number.
  • All profile settings are set to Active.
  • Time alarm (5 to 30 minutes) and pre alarm (30 to 120 seconds) are within the permitted range.
  • The phone number of the alarm receiving centre is entered.
  • At least one alarm receiver is entered.

If all lines are green, the profile complies with the pre-standard. Red crosses show what is still missing.

Good to know

FAQ

Why does the profile show the pre-standard as not fulfilled?

Read the list at the top. Each red cross names what is missing, for example the phone number of the alarm receiving centre or a device without a phone number.

Why is no email sent in an alarm?

The profile has no active notification rule. Create one using the link in the warning above the list.

Which values are correct?

Time alarm: 5 to 30 minutes. For the pre alarm, the field allows 30 to 240 seconds, but the VDE check at the top of the profile requires 30 to 120 seconds. If in doubt, stay at 120 seconds or less and the check will be green.

Does lone worker protection work on iPhones?

Not at the moment. The portal points this out itself: lone worker protection does not support iOS devices.