Hilfe

Create and set up an alarm profile | COREDINATE Help

Written by Ricarda Schmidt | Nov 25, 2026, 8:13:24 PM

Updated 25 Nov 2026 · Portal 9.34 · Lone Worker Protection · 6 min

In this article

  • Create an alarm profile and open its settings
  • Each setting in detail and when to switch it on
  • Two example profiles for devices with and without an alarm button
  • What to watch out for with the alarm receiving centre's phone number

An alarm profile defines when a device triggers an alarm in lone worker protection and how strict the monitoring is. What an alarm profile is in general and how the VDE check works is explained in What is an alarm profile?.

This article goes through the settings one by one. It helps you decide which switches suit your operation. A wrongly chosen switch can otherwise cause false alarms or lock employees out of the app.

Prerequisites

  • You are allowed to create and edit alarm profiles. This right unlocks the Lone Worker Protection menu and Alarm profiles.
  • Lone worker protection is activated for your company.
  • The devices to be monitored are Android devices. Lone worker protection currently does not support iOS devices.

Step 1: Create an alarm profile

Open Lone Worker Protection and then Alarm profiles. Click Create alarm profile, enter a Name and click Create.

Open the new profile from the list. The Settings are on the General tab. Click the pencil in the top right, change the values and click Save. Reset discards your changes.

Step 2: The settings in detail

Permanent connection check

The app constantly checks whether the device is connected to the server. If the connection fails for more than 5 minutes, a technical alarm is triggered.

Only switch this on if there is network coverage everywhere on site. In underground car parks, basements or shielded halls it will otherwise cause false alarms.

Alarm / panic button on the device

Pressing the alarm button triggers an alarm immediately. This only works with certain devices such as the Crosscall Core M5. Not every device with a red button works, because some manufacturers assign the button permanently. Our sales team can advise on suitable devices.

Inactivity until time alarm

If nothing happens in the app during this time, the device triggers a time alarm. Scanning a checkpoint or tapping the display in the app resets the timer. Values from 5 to 30 minutes are allowed.

Pre alarm

The pre alarm warns the employee shortly before the time alarm. They can reset it to show that everything is fine. The pre alarm is part of the inactivity time.

Example: time alarm 5 minutes, pre alarm 30 seconds. After 4 minutes 30 seconds without activity, the pre alarm sounds. If the employee does not respond within 30 seconds, the time alarm follows.

Requires active alarm receiver

If this is switched on, the app sends a test alarm after login. The employee can only start work once an alarm receiver has confirmed it in the Receiving Center.

Only switch this on if the Receiving Center is staffed around the clock. Otherwise nobody can get into the app.

Operating condition can be reset by lone worker.

Despite its name, switching this on means the employee may not put the device back into operation themselves after an alarm. It is released in the Receiving Center instead. This applies to time alarms and the alarm button, not to the pre alarm.

Again, only switch this on if someone is permanently logged in to the Receiving Center.

Phone of the alarm receiving center

The device dials this number automatically when the alarm button is pressed. Choose the country code and enter the number. The device needs an active SIM card for the call to go through.

Caution: this is an automatic dialling system. In Germany it is prohibited to enter public emergency numbers such as 110 or 112. Check the rules that apply in your country as well.

Step 3: Assign devices and receivers

Assign devices to the profile on the Monitored devices tab. How this works and what happens when a device moves between profiles is explained in Add or remove a monitored device.

On the Alarm receiver tab, click Add receiver and select the people who respond in an alarm.

Example: two profiles for different devices

  • Profile without alarm button: time alarm, pre alarm and phone number active, Alarm / panic button on the device off. Requires active alarm receiver can still be on; login works once the test alarm has been confirmed.
  • Profile with alarm button: as above, plus Alarm / panic button on the device switched on. Only assign devices with a suitable button here.

A device can only ever be in one profile. Separate profiles are therefore the way to protect different devices in different ways.

Good to know

  • You do not have to meet the VDE V 0825-11 pre-standard, not even for the German VBG premium scheme. The check at the top of the profile only shows whether your profile complies with it.
  • For the check, the pre alarm must be between 30 and 120 seconds. The input field allows up to 240 seconds under the DIN standard.
  • If a warning appears above the profile list, at least one profile has no active notification rule. No email is sent in an alarm. The link in the warning takes you straight to the notification rules.
  • If you delete a profile, none of its assigned devices are monitored any longer.

FAQ

Why can't an employee log in to the app?

Most likely Requires active alarm receiver is switched on and nobody has confirmed the test alarm in the Receiving Center. Staff the Receiving Center or switch the setting off.

Why do we keep getting technical alarms?

The Permanent connection check reports every connection loss of more than 5 minutes. If network coverage on site is poor, switch it off.

Can I enter 112 as the alarm receiving centre's number?

No. In Germany, automatic dialling systems must not call public emergency numbers. Enter the number of your control room or alarm receiving centre instead.

What values make sense for the time alarm and pre alarm?

The time alarm can be 5 to 30 minutes. For a green VDE check, choose a pre alarm between 30 and 120 seconds.

Related articles